Bộ điều khiển nhiệt độ kiểu Module SRZ RKC - Temperature Controllers RKC Instrument

Xuất xứ:
Nhật Bản - Japan
Hotline:
0917 410 069
Email:
sale17@tmpvietnam.com
Nhà cung cấp:
Đại lý phân phối RKC Instrument tại Việt Nam
Mã sản phẩm:
SRZ RKC Instrument

SRZ RKC InstrumentTemperature Controllers

Bộ điều khiển nhiệt độ kiểu Module RKC Instrument

Advantages 

  • Measurement accuracy: ±0.2% of displayed value
  • Sampling time: 0.25 sec.
  • 4-channel control per module
  • Front loader communication port
  • Digital Input/Output and CT Input Modules
  • Communication converters of various field bus communication can be connected.

Bộ điều khiển nhiệt độ kiểu Module SRZ RKC - Temperature Controllers RKC Instrument

Main specification

Temperature control module (Z-TIO)

  • Number of Inputs :4 points or 2 points
  • Input type (Universal input within each group) ※See the Input Range Code for the input range.
    1) Thermocouple: K, J, R, S, B, E, N, T, W5Re26/W26Re, PLII
    2) RTD: Pt100, JPt100 (3-wire system)
    3) DC voltage (Low): 0 to 10mV, 0 to 100mV, 0 to 1V
    4) DC current: 0 to 20mA, 4 to 20mA
    5) DC voltage (High): 0 to 5V, 1 to 5V, 0 to 10V
  • Sampling time : 0.25 sec.
  • Measurement accuracy : ±(0.2% of displayed value+1 digit ※Depends on the input and the range.
  • Outputs 1 and 2 (OUT1, 2)
    1) Relay contact output: 1a contact
    2) Voltage pulse output for SSR driving: 0/12V dc
    3) DC Current output: 0 to 20mA, 4 to 20mA dc
    4) DC voltage output: 0 to 5V, 1 to 5V, 0 to10V
    5) SSR (Triac) output : Output: Current rating: 0.5A
    6) Open collector output: Sink type
  • Event (alarm) function: Max.4 points ※Including LBA function
  • Communication function: RS-485
  • Optional functions: Output distribution function, Nice MEET function, Automatic temperature rise function, Peak current suppression function
  • Master-slave function, SV selection function (Remote SV, Ratio setting, Cascade control)

<Specification of Options>

  • CT input for heater break alarm (Max.4 points) ※Can be used for time proportioning output and continuous output.

General Specification

  • Power supply voltage (Rating): 24V dc
  • Ambient temperature: -10 to 55°C
  • Weight:

Screw terminal type:Approx.160g

Connector type: Approx.140g

  • Safety standards:UL UL61010-1

cUL CAN/CSA-22.2 NO.61010-1

CE Marking: Low Voltage Directive (LVD) EN61010-1

EMC Directive EN61326-1

RCM EN55011

Digital Input/Output module (Z-DIO)

  • Digital inputs: ※See Input assignment table for model
    Number of inputs: 0 or 8 points
    Input method: Voltage contact input, Sink type
  • Digital outputs: ※See Input assignment table
    Number of outputs: 0 or 8 points
    Output types: 1) Relay contact output, 1a contact
    2) Open collector output, Sink type
  • Communication function: RS-485

<General Specification>

  • Power supply voltage (Rating): 24V dc
  • Ambient temperature: -10 to 55°C
  • Weight: Screw terminal type: Approx.150g
    Connector type: Approx.130g
  • Safety standards:UL UL61010-1

cUL CAN/CSA-22.2 NO.61010-1
CE Marking: Low Voltage Directive (LVD) EN61010-1

EMC Directive EN61326-1

RCM EN55011

Current transformer input module (Z-CT)

  • Number of input: 12 points
  • Input type : CTL-6-P-Z (for 10A), CTL-6-P-N (for 30A), CTL-12-S56-10L-N (for 100A)
  • Number of heater break alarm: 12 points (1 point per CT input)
    ※with Heater break alarm and automatic setting function of overcurrent alarm
  • Communication function: RS-485

<General Specification>

  • Power supply voltage (Rating): 24V dc
  • Allowable ambient temperature: -10 to 55°C
  • Weight: Screw terminal type: Approx.160g  Connector type: Approx.140g
  • Safety standards:UL UL61010-1

cUL CAN/CSA-22.2 No.61010-1
CE Marking: Low Voltage Directive (LVD) EN61010-1

EMC Directive EN61326-1

RCM EN55011

※Caution when using Z-TIO-C/D and Z-COM with Z-CT
Z-CT module is not available for PLC communication of Z-TIO-C/D. Host communication is required to verify the data.
When using Z-COM with PLC communication, communication data on the Z-CT needs to be assigned. In this case, our Register Mapping Tool (ZEAL2) is necessary to assign register addresses.

※Over Current Alarm Function of Z-CT module
The Over Current Alarm status of the Z-CT module is NOT output from the Z-DIO module. It can be checked only through communication.

Extended communication module (Z-COM)

  • Number of connecting modules: 16 modules or less in case of the same function, Total 31 modules or less.
  • RKC standard communication: RS-485 / RS-422A
  • MODBUS communication: RS-485 / RS-422A
  • PLC communication (MAPMAN): RS-485/ RS-422A
  • Supported models
    1) Mitsubishi Electric, AnA / QnA / Q series
    AnA / AnUCPU common commands (QR / Q)
    (0401/1401) (ZR register only)
    A series / FX2N / FX2NC series
    ACPU common commands (QR / QW)
    2) OMRON SYSMAC series
    C-mode command (RD / WD)
  • Number of maximum connection: 4 modules

<General Specification>

  • Power supply voltage (Rating): 24V dc
  • Allowable ambient temperature: -10 to 55°C
  • Weight: Approx.110g
  • Safety standards:UL UL61010-1

cUL CAN/CSA-22.2 NO.61010-1

CE Marking: Low Voltage Directive (LVD) EN61010-1

EMC Directive EN61326-1

RCM EN55011

Bình luận của bạn
*
*
*
*
 Captcha
Chia sẻ:
Danh mục sản phẩm
Thống kê truy cập
  • Trực tuyến:
    105
  • Hôm nay:
    5464
  • Tuần này:
    11091
  • Tuần trước:
    35719
  • Tháng trước:
    41183
  • Tất cả:
    3716189

CÔNG TY TNHH THƯƠNG MẠI VÀ DỊCH VỤ TĂNG MINH PHÁT

Văn phòng Giao dịch: Số 1, Đường số 27, Phường Hiệp Bình Chánh, TP Thủ Đức, TP HCM.
Email: sale17@tmpvietnam.com
Điện Thoại: 0917 410 069 - 0972 182 449

MẠNG XÃ HỘI :  Thông tin cuối website Thông tin cuối website Thông tin cuối website Thông tin cuối website

© 2018 Tang minh Phat , all rights reserved.