Bộ điều khiển nhiệt độ RKC FB100, FB400, FB900 - Process and Temperature Controllers
FB Series RKC Instrument | Digital Controllers (Process and Temperature Controllers)
Bộ điều khiển nhiệt độ RKC FB Series | Bộ điều khiển kỹ thuật số RKC FB Series
Advantages FB Series
- Measurement accuracy: ±0.1% of displayed value
- Sampling time: 0.1 sec.
- Abundant event inputs/outputs
- Loader communication
- Intercontroller Communication
- Plug-in construction
Main features FB Series
Abundant Inputs/Outputs
Varieties of combinations of various optional inputs/outputs
Link operation through communication
Various types of link operation are available through intercontroller communication.
- Automatic temperature rise group with learning function
- Temperature ratio setting
- Cascade control
- Group RUN/STOP function
Selectable from two types of PID control; “Response focused” and “Follow-up focused”
- PV-derivative PID control (Response focused) and deviation derivative PID control (Follow-up focused)
Enhanced new heat/cool PID control with enhanced undershoot suppression (USS) on the cooling side.
- Undershoot Suppression Function (USS) is installed in the cooling control.
- ※USS:Undershoot Suppression Dedicated control algorithm for water-cooling or air-cooling is selectable.
Loader communication
- All models are equipped with loader communication function.
- Configuration data management software (PROTEM2) is available
Main specification
- Number of Inputs : 1 point
- Input type (Universal input) : ※See the Input Range Code for the input range.
1) Temperature, DC current, DC voltage (low) input group
Thermocouple: K, J, R, S, B, E, N, T, W5Re/W26Re, PLII, U, L
RTD: Pt100 or JPt100
DC voltage (low): 0 to 10mVdc, -10 to +10mVdc, 0 to 100mVdc, -100 to 100mVdc, 0 to 1Vdc
DC current input group: 0 to 20mAdc, 4 to 20mAdc
2) DC voltage input (high) group:-1 to 1Vdc, 0 to 5Vdc, 1 to 5Vdc, 0 to 10Vdc
- Sampling time: 0.1 sec. ※Also switchable to 0.05 sec. and 0.25 sec.
- Measurement accuracy : ±(0.1% of displayed value+1 digit) ※Depends on the input and the range.
- Output 1 (OUT1)
1) Relay contact output : 1a contact
2) Voltage pulse output for SSR driving: 0/12Vdc
3) DC Current output : 0 to 20mA, 4 to 20mA
4) DC voltage output: 0 to 5V, 1 to 5V, 0 to10V
5) SSR (Triac) output : Current rating: 0.5A
6) Open collector output: Sink type
<Specification of Options>
- Output 2 (OUT2) ※ Control, Event, HBA, and FAIL can be assigned to output
1) Relay contact output : 1a contact
2) Voltage pulse output for SSR driving: 0/12Vdc
3) DC Current output : 0 to 20mA, 4 to 20mA
4) DC voltage output: 0 to 5V, 1 to 5V, 0 to10V
5) SSR (Triac) output : Current rating: 0.5A
6) Open collector output: Sink type - Digital outputs 1 to 4 (DO1 to 4)※Digital outputs 1 to 2 (DO1 to 2) for FB100
※Event, HBA, and FAIL can be assigned to output.
Relay contact output: 1a contact - Event function (Max.4 points): Temperature alarm, Control loop break alarm (LBA)
- CT input for Heater break alarm (Max.2 points)
- Analog retransmission output (Max. 1 point): 0 to 20mA, 4 to 20mA, 0 to 1V, 0 to 5V, 0 to 10V, 1 to 5Vdc
- Digital inputs: (Max.7 points) ※Function is selectable from the Event input logic selection table
- Communication interface: RS-485 / RS-422A / RS-232C ※RS-485 only for FB100
- Power feedforward input: ※Available except FB100
- Feedback resistance (FBR) input: 100 to 10kΩ (135Ω as standard)
<General Specification>
- Power supply voltage (Rating): 100 to 240Vac/24Vac/24Vdc
- Ambient temperature: -10 to 50°C
- Weight:
FB100 Approx.150g
FB400 Approx.230g
FB900 Approx.290g
- Safety standards: UL UL61010-1
cUL CAN/CSA-22.2 NO.61010-1
CE Marking: Low Voltage Directive (LVD) EN61010-1
EMC Directive EN61326-1
RCM EN55011
- AT2E
- MEGGITT Vibro-Meter
- ASHCROFT
- BIRCHER
- BURKERT
- BECKHOFF
- BAUMER
- SAUTER
- CS INSTRUMENTS
- COMETSYSTEM
- CEMB
- FAIRCHILD
- ORBINOX
- KRACHT
- TEK-TROL
- REDLION
- TAKENAKA
- LABOM
- MKS Anlasser
- NIRECO
- MATSUSHIMA
- LAPAR
- IBA AG
- KIEPE
- SPOHN BURKHARDT
- MARK-10
- PULS POWER
- VEGA
- SCHENCK PROCESS
- NORGREN
- MINIMAX
- GASTRON
- GEMU
- ENDRESS HAUSER ( E + H )
- TDK-LAMBDA
- KROHNE
- PORA
- FIREYE INC
- RECKMANN
- SITEC
- KELLER ITS
- DWYER
- KOGANEI
- AIRA INDIA
- LAND AMETEK
- BRONKHORST
- STI Vibration
- GESSMANN
- OKAZAKI
- MAXCESS
- Baumuler
- ROMER FORDERTECHNIK
- Bihl+Wiedemann
- MEDENUS
- HELUKABEL
- THIẾT BỊ PHÒNG THÍ NGHIỆM
- KNICK
- FSM AG
- CÁP ĐIỀU KHIỂN
- DMN WESTINGHOUSE
- IDM Instrument
- Xenoenergy
- HIFLUX FILTRATION
- WAREX VALVE
- Scheuch Việt Nam
- BLOCK
- UNIVERSAL HYDRAULIK
- VDL Industrial
-
MỘT SỐ BRAND KHÁC
- INTORQ - LENZE
- METRIX VIBRASION
- WESTLOCK CONTROLS
- WEST CONTROL
- Honeywell
- Jumo
- VALPES
- OMEGA
- KOSO
- WAGO
- Badger Meter
- Nagano Keiki
- Yamato Scale
- NETTER VIBRATION
- Kromschroder
- Ateg Automation
- Bruel Kjær Vibro
- Schrack Technik
- Vacuum Barrier
- Met One Instruments
- Rosemount
- FISHER VIỆT NAM
- NDC Technologies
- Baumuller
- Ramen Valves AB
- CONCH Electronic
- LIQUIFLO
- ROPEX Industrie-Elektronik
- PIL Sensoren
- SCHNEIDER SERVOHYDRAULICS
- Optek-Danulat
- Rotary Valve Gericke
- Gericke
- CMO Valves
- COMAV SRL
-
Trực tuyến:89
-
Hôm nay:5057
-
Tuần này:10684
-
Tuần trước:35719
-
Tháng trước:40776
-
Tất cả:3715782