Bộ điều khiển nhiệt độ SA100 RKC Instrument - Temperature controllers RKC Instrument

Hotline:
0917 410 069
Email:
sale17@tmpvietnam.com
Nhà cung cấp:
Đại lý phân phối RKC Instrument tại Việt Nam
Xuất xứ:
Nhật Bản - Japan
Mã sản phẩm:
SA100 RKC Intrumment

SA100 RKC Instrument | Temperature controllers

Bộ điều khiển nhiệt độ SA100 RKC Instrument | Bộ điều khiển kỹ thuật số SA100 RKC Instrument

Main features SA100 RKC Instrument

DIN rail mounting type temperature controller

Installable on the DIN rail inside the control cabinet. Removable terminal socket for easy maintenance.

Control state discriminating type self-tuning

PID parameters are automatically tuned when control is determined to be disturbed Autotuning function is also available

Two outputs can be assigned to control output, alarm output, or analog retransmission output

This instrument can be used as a temperature controller, an alarm, or an overtemperature protection device depending on the output assignment.

Bộ điều khiển nhiệt độ SA100 RKC Instrument - Temperature controllers RKC Instrument

Main specification SA100 RKC Instrument

  • Number of Inputs :1 point
  • Input type : ※See the Input Range Code for the input range.
    1)Thermocouple : K, J, T, S, R, E, B, N, W5Re/W26Re, U, L, PLII
    2)RTD: Pt100 or JPt100
    3)DC voltage: 0 to 5V dc, 1 to 5V dc
    4)DC current: 0 to 20mA dc, 4 to 20mA dc ※ A 250Ω external resistor is required.
  • Sampling time: 0.5 sec.
  • Measurement accuracy:±(0.3% of displayed value+1 digit) ※Depends on the input and the range.
  • Output (OUT1) ※To be assigned from a control output, an alarm output, or an analog retransmission output.
    1) Relay contact output : 1a contact
    2) Voltage pulse output for SSR driving: 0/12V dc
    3) DC Current output : 0 to 20mA, 4 to 20mA dc

<Specification for Optional Functions>

  • Output2(OUT2)※To be assigned from a control output or an alarm output.
    1) Relay contact output : 1a contact
    2) Voltage pulse output for SSR driving: 0/12V dc
  • Alarm outputs (max.2 points): Temperature alarm or Control loop break alarm
  • External contact inputs (max.2 points): RUN/STOP switching or SV1/SV2 switching
  • Communication function: Communication method RS-485

<General Specification>

  • Power supply voltage (Rating): 100 to 240V ac/24Vac/24Vdc
  • Ambient temperature: 0 to 50°C
  • weight: Approx.120g (excluding a socket)
  • Safety standards: UL UL61010-1

cUL CAN/CSA-22.2 NO.61010-1

CE Marking: Low Voltage Directive (LVD) EN61010-1

EMC Directive EN61326-1

RCM EN55011

Bình luận của bạn
*
*
*
*
 Captcha
Chia sẻ:
Danh mục sản phẩm
Thống kê truy cập
  • Trực tuyến:
    88
  • Hôm nay:
    5288
  • Tuần này:
    10915
  • Tuần trước:
    35719
  • Tháng trước:
    41007
  • Tất cả:
    3716013

CÔNG TY TNHH THƯƠNG MẠI VÀ DỊCH VỤ TĂNG MINH PHÁT

Văn phòng Giao dịch: Số 1, Đường số 27, Phường Hiệp Bình Chánh, TP Thủ Đức, TP HCM.
Email: sale17@tmpvietnam.com
Điện Thoại: 0917 410 069 - 0972 182 449

MẠNG XÃ HỘI :  Thông tin cuối website Thông tin cuối website Thông tin cuối website Thông tin cuối website

© 2018 Tang minh Phat , all rights reserved.